  • 產(chǎn)品名稱:Vermason 222547校準(zhǔn)器

  • 產(chǎn)品型號:用于校準(zhǔn)手腕帶和工鞋接地測試儀
  • 產(chǎn)品廠商:其它品牌
  • 產(chǎn)品文檔:
你添加了1件商品 查看購物車
簡單介紹:
Vermason 222547校準(zhǔn)器 Calibration Unit for Vermason Wrist Strap and Footwear Tester用于校準(zhǔn)手腕帶和工鞋接地測試儀適配儀器:222504, 222506,222507, 222562, 222563, 222564, 222565,Vermason(DESCO子品牌)
詳情介紹:

Vermason 222547校準(zhǔn)器 Calibration Unit for Vermason Wrist Strap and Footwear Tester
用于校準(zhǔn)手腕帶和工鞋接地測試儀
適配儀器:222504, 222506,222507, 222562, 222563, 222564, 222565
Vermason(DESCO子品牌)

Operation
The Tester Calibration Unit was specifically designedfor use in calibration of Vermason brand equipment.The following procedures will not cover adjustment of
the test equipment. For detailed information regardingadjustment of specific Vermason brand testers, pleasecontact Desco Europe Customer Service.

Frequency of recalibration should be based on thecritical nature of those ESD sensitive items handled andthe risk of failure for the ESD protective equipment andmaterials. In general, we recommend that calibration be
performed annually.

Testing the Compact Tester
WRIST STRAP CIRCUIT
1. Connect the 10 mm lead from the Calibration Unitto the wrist strap stud on the Compact Tester.
2. Select 715K FAIL LOW on the Calibration Unit.
3. Press and hold the Calibration Unit’s test probeon the Compact Tester’s test plate. The testershould indicate a FAIL LOW condition.
4. Select 785K PASS LOW on the Calibration Unitand repeat the test. The tester should indicate aPASS condition.
5. Select 33M PASS HIGH on the Calibration Unitand repeat the test. The tester should indicate aPASS condition.
6. Select 37M FAIL HIGH on the Calibration Unitand repeat the test. The tester should indicate aFAIL HIGH condition.

FOOTWEAR CIRCUIT
1. Connect the 10 mm lead from the Calibration Unitto the 10 mm footwear stud on the Compact Tester.
2. Select 715K FAIL LOW on the Calibration Unit.
3. Press and hold the Calibration Unit’s test probeon the Compact Tester’s test plate. The testershould indicate a FAIL LOW condition.
4. Select 785K PASS LOW on the Calibration Unitand repeat the test. The tester should indicate aPASS condition.
5. Select 33M PASS HIGH on the Calibration Unitand repeat the test. The tester should indicate aPASS condition.
6. Select 37M FAIL HIGH on the Calibration Unit andrepeat the test. The tester should indicate aFAIL HIGH condition

姓名:
電話:
您的需求:
 
久久推油| 菠萝蜜污视频免费看小草影院| 97久操| 婷婷大胆少妇| 极品熟女一区二区| 三 级 片 合集| 殴美一区二区黄片| 另类老熟妇X| 欧美h福利视频| 草逼视频免费看不卡| 日逼视频粉嫩高潮| 精品人妻一区二区三区奶水| 伊人九九综合| 成人日韩美女、| 激情深爱五月丁香网| 国产亚州欧美视频| 日韩人妻电影在线| 91麻豆sh视频| 欧美亚洲自拍偷拍中文在线| 天天久久久久| 亚洲天堂12| 天堂一区91| 人妻大黑香蕉| 在线国产日韩欧美精品三级| av男人天堂网址| 亚洲AV综合色区无码专天天夜| 三区一级黄片| 秋霞区一区二区三区| 欧美午夜午夜福利| 狠狠躁夜夜爽| www.熟妇av.com| 人妻电影射了爽了| 五月丁香爱婷婷| 香蕉青青草| 国产综合一区中文字幕| 永久免费视频,日B视频| 国产二区 自拍| 五月丁香/| 亚洲成人1区| 精品乱伦一区二区三区| 极品人妻内射|